Infant / Pediatric ventilator
 



Çü¸í:
SECHRIST MILLENNIUM


From Sechrist Industries comes
the Millennium¢ç; - the infant / pediatric ventilator for the next century.
Designed for maximum performance and
user-friendly convenience,
for which Sechrist has always been known.
The Millennium¢ç; combines state-of-the-art electronics with the simplicity of pressure sensing technology. The result: simple, reliable ventilation for all your neonatal, infant, and pediatric patient requirements.


Reliable, Versatile, Simple. Just by looking at the Millennium¢ç; you can tell how easy it is to use.

Ventilation modes such as SIMV/IMV, Assist Control, and Backup ventilation in CPAP make the

Millennium¢ç; the optimal choice in basic, reliable neonatal, infant and pediatric ventilation.

Synchronization for even the smallest child. What sets the Millennium¢ç; apart is the patented SmartSync¢â, a unique pressure sensing device that synchronizes the patient's natural breathing cycle with the ventilator. It has a maximum sensitivity of 0.10 cmH20, and a response time of 5-40 milliseconds depending upon the sensitivity settings. With this technology from a company you've known and trusted for decades, you can be certain the Millennium¢ç; will provide your patients with unparalleled performance.

Recommended Applications:   Neonatal, infant& pediatric patients < 50 Kg
Flow:   2-32 lpm; flush 40 lpm
Modes of operation:   AC, SIMV/IMV, CPAP, CPAP with backup ventilation, Standby
Inspiratory Time:   0.1 to 3.0 seconds
I:E Ratio:   Normal Range:
    1:1.0 to 1:10 (sens. off)
    1:1.0 to 1:99 (sens. on)
    Inverse Range:
    1.0:1 to 4.0:1
Rate:   2 to 150 breaths per minute
Expiratory Pressure:   0 to 20 cmH2O
Inspiratory Pressure:   5 to 70 cmH2O
Waveform:

  Tappered to square
Manual Breath:   Electronically controlled, based upon the inspiratory pressure, inspiratory time and waveform control setting
Alarms:   High Inspiratory Pressure
    Low/Prolonged Inspiratory Pressure
    Low PEEP/Baseline Pressure
    Apnea
    High Respiratory Rate
    Loss/Low Electrical Power
    System Error/Vent Inop
    Loss of Inlet Gas
Alarm Delay:   3 to 15 seconds
Alarm Mute:   30 Seconds
Safety Pressure Relief Valve:   15 to 85 cmH20
Indicators:   Inspiratory Pressure
    PEEP/Baseline Pressure
    Calculated I:E Ratio
    Mean Airway Pressure
    Proximal Airway Pressure Bar Graph
    Measured Respiratory Rate
Dimensions:   13.5"(34.29cm)H 11"(27.94cm)W 9.5"(24.13cm)D
Weight:   21 lbs (9.5kg)
Gas Consumption:   14 lpm above the continuous flow setting
Power Requirements   110 to 120 VAC, 50/60 Hz
    220 to 240 VAC, 50/60 Hz
    100 VAC, 50/60 Hz
     
Product   Part No.

Ventilator, Millennium, English Language   20409-1
Ventilator, Millennium, Spanish Language   20409-2
Millennium Battery Pack   21513
Smartsync™ Patient Sensing Device,   20417
Millennium®, Single Patient Use, Carton of 12