The
built-in displays provide easy-to-read continuous ventilation
parameter information.
The alarm system is comprehensive, but avoids information overload
during alarm conditions.
To prevent inadvertent PEEP when higher flow rates are required,
a special exhalation value block and pediatric circuit are available.
The philosophy at Sechrist Industries, Inc.
is to design and manufacture
the highest quality medical devices to meet your respiratory
care needs.
The Model IV-100B Infant Ventilator accomplishes this goal
with time proven safety and reliability.
The IV-100B is capable of meeting the most
demanding requirements of the intensive care unit.
You can ventilate newborn to pediatric patients with precise
control of oxygen concentration,
at respiratory rates of 1 to 150 breaths per minute.
The Inspiratory and Expiratory Pressure controls are non-interactive.
A simple, yet comprehensive alarm system monitors the parameters
you have set up and notifies you of significant changes.
Recommended
Applications: |
|
Neonatal,
Infant, and Pediatic Ventilation |
Flow: |
|
0-32
LPM, Flush 40 LPM |
FiO2:
|
|
0.21
to 1.00 |
Mode: |
|
OFF,
CPAP, VENT |
Inspiratory
Time: |
|
0.10
to 2.90 sec. |
Expiratory
Time: |
|
0.30
to 60.0 sec. |
I:E
Ratio: |
|
10:1
to 1:600 (Readout 1:0.1 to 1:99) |
Rate: |
|
1
to 150 BPM |
Expiratory
Pressure: |
|
2
to 20 cm H2O; Zero Baseline possible at 24 LPM and higher
rates |
Inspiratory
Pressure: |
|
5
to 70 cm H2O |
Manual
Breath: |
|
Yes |
Alarm: |
|
Independent
for Microprocessor; Low Airway Pressure, Leaks, Patient
Disconnect, Fail to Cycle, Apnea, Prolonged Inspiration,
and Peak Overpressure |
Alarm
Delay Time: |
|
3
to 60 sec. |
Alarm
Mute: |
|
30
sec. ± 5 sec. |
Safety
Pressure Relief Valve: |
|
Yes
(adjustable) |
Indicators: |
|
Inspiratory
Time, Expiratory Time, I:E Ratio, Rate, Inspiratory Phase,
Inverse I:E Ratio, Mode Selection, Alarm, High and Low
Alarm Set Points, and Mean Airway Pressure |
Manual
Teats: |
|
Checks
microprocessor function, displays, alarm function |
Safety
Auto Lock-Out Circuit: |
|
Yes,
Inspiratory Phase terminated at 4 sec. Even if microprocessor
fails |
Timing
Pre-Set: |
|
Yes |
Dimensions: |
|
Height:
13" (33.02 cm) |
|
|
Width:
14" (35.56 cm) |
|
|
Depth:
9" (23.00 cm) |
Weight: |
|
Net:
21 lbs. (9.54 Kg) |
|
|
Shipping:
30 lbs. (13.63 Kg) |
Power
Requirements: |
|
117
VAC 50/60 Hz, Circuit Breaker Protected, 3-Wire SJT Power
Cord Provided, Hospital-Grade Plug, Current leakage less
than 20 micramps when tested per UL 544
|
Transport
Power Requirements:
|
|
12
VDC 1.2 amps |
Ventilator,
IV100B, 117V, Mech. Manometer, English Language |
|
IV100B-M |
Ventilator,
IV100B, 220V, Mech. Manometer, English Language |
|
IV100B-MI |
Ventilator,
IV100B, 220V, Mech. Manometer, Spanish Language |
|
20395 |
Ventilator,
IV100B, 117V, Elect. Manometer, English Language |
|
20123 |
Ventilator,
IV100B, 117V, Elect. Manometer, Spanish Language |
|
20396 |
Ventilator,
IV100B, 220V, Elect. Manometer, English Language |
|
20129 |
Ventilator,
IV100B, 220V, Elect. Manometer, Spanish Language |
|
20397 |
|